IPX7 32.3*44.3mm LK-C65B 18.5um RVG Dental X Ray Sensor

Zhengzhou Linker Medical Equipment Co., Ltd.
Contact Now

IPX7 32.3*44.3mm LK-C65B 18.5um RVG Dental X Ray Sensor

  • 1
  • 2
  • 3

Brand Name : Handy

Model Number : LK-C65B

Certification : CE/ISO/FDA

Place of Origin : China

MOQ : 1piece

Price : Negotiable

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 2000piece/month

Delivery Time : 1-3 working days

Packaging Details : 1 Pcs/box Size:26*28*8cm Weight: 2kg/piece

Active Area : 32.3*44.3mm

Image Pixel : 2.7m(1920*1440)

Pixel Size : 18.5um

Operation System : Windows2000/XP/Win7/Win8/Win10

Contact Now

LK-C65B HDR-600 CE FDA Approved RVG Dental XRay Sensor 32.3*44.3mm Twain Driver

 

The Digital dental X-ray imaging system is intended to generate intraoral x-ray
image ,require to working with x-ray source and imaging software in dental clinic for
dentist and orthodontists.

 

 

 

Packinglist
 
Manual 1pc
CD 1pc
X-Ray Sensor with controller 1pc
Holder 1pc
Sleeves 1 bag

 

IPX7 32.3*44.3mm LK-C65B 18.5um RVG Dental X Ray Sensor

 

IPX7 32.3*44.3mm LK-C65B 18.5um RVG Dental X Ray Sensor

Safety Classifications
 
Safety Type: Class-Ⅱ BF
Power: DC5V Maximum 600MA.Rate of Work: Max 1W
Degree of protection against ingress of water: IPX7
Non AP equipment, non APG equipment
Mode of operation: Continuous operation
 
Operating conditions
 
Environment Temperature +10℃~+40℃
Environment relative humidity ≤95%
Air pressure 860hPa~1060hPa
 
Transport and Storage conditions
 
Environment Temperature -25℃+60℃
Environment relative humidity 10%~93%
Air pressure 860hPa~1060hPa
 
IPX7 32.3*44.3mm LK-C65B 18.5um RVG Dental X Ray Sensor
 

 
 
 

 

Protect Sensor from Potential ESD Damage
 
Like other electronic devices, Sensor is susceptible to electrostatic discharge (ESD),
particularly when the device is used in or around carpeted areas or low humidity
environments. During cable replacement, when Sensor contacts are exposed, it is
especially important to protect the device from potential ESD damage. Touching a
metal surface prior to replacing the cable will reduce the risk of damaging Sensor
components by accidental static discharge. The use of anti-static floor mats or floor
treatments (for example Staticide 6005/6002) will also help eliminate static build-up
in your office.
 
Do Not Touch Exposed Connectors on Non-Medical
Equipment and the Patient at the Same Time
 
When the Sensor and controller are in use, avoid touching exposed connectors on
non-medical electrical equipment and the patient at the same time. The human body is
capable of conducting electrical current and may cause a shock hazard to patients if
appropriate safety practices are not observed

 

IPX7 32.3*44.3mm LK-C65B 18.5um RVG Dental X Ray Sensor

 
Ensure Proper System and PC Workstation
Installation and Operation
 
The Sensor and controller have been determined to be in accordance with
international safety standards and are deemed suitable for use within the patient area,
which extends from the patient for a distance of 5 ft (1.5m). To comply with these
standards, do not operate non-medical equipment (such as a PC workstation) inside
the patient area. Outside the patient area, the presence of approved non-medical grade
equipment and Listed / Approved / IEC 60950-1 certified Information Technology
Equipment (ITE) computer equipment is acceptable. The host computer (PC
3workstation) should be CE-approved and conform to the Low
Voltage [73/23/EC] and EMC Directive [89/336/ERC]. The system shall be in
accordance with IEC60601-1-1. The person connect the product
to the host computer shall insure its compliance. Also, to help ensure optimal
performance, ensure that all software programs residing on the workstation are
virus-free and have been adequately tested so they will not impact imaging
applications after installation. Any questions please contact your local distributor
 

Besides, we have some other related dental items:X ray sensor, portable X ray unit and X ray scanner etc

 

 

 

IPX7 32.3*44.3mm LK-C65B 18.5um RVG Dental X Ray Sensor

IPX7 32.3*44.3mm LK-C65B 18.5um RVG Dental X Ray Sensor

 


Product Tags:

RVG Dental X Ray Sensor

      

18.5um Dental X Ray Sensor

      

LK-C65B

      